Communication Manager Maintenance-Object Repair Procedures
1726 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Packet Bus Port Health Inquiry Test (#567)
This test verifies that the packet-bus fault-detection and maintenance function of the M/T-PKT is
functioning properly. This is done by having the M/T-PKT perform a self-test. If the self-test
passes, then the Packet Bus Port Health Inquiry test passes. If the self-test fails or
Communication Manager cannot communicate with the M/T-PKT, then the test fails
Table 640: Test #567 Consistency Test
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources necessary to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT An internal operation failed, and the test could not be completed.
1. Retry the command at 1-minute intervals up to 5 times.
2059 FAIL The M/T-PKT has reported a failure of the on-board self-test.
2060 FAIL The M/T-PKT has reported an invalid state for the packet bus.
2061 FAIL Communication Manager cannot communicate with the M/T-PKT, but
can communicate with the Maintenance/Test circuit pack.
1. Retry the command.
2. If the test continues to fail, replace the Maintenance/Test circuit pack,
and retry the command.
3. If the test continues to fail, seePKT-BUS (Packet Bus)
on page 1790
or PKT-INT (Packet Interface)
on page 1799 to determine whether
the M/T-PKT failure is being caused by a packet-bus fault.
PASS The M/T-PKT packet-bus fault-detection capability is operating correctly.