Communication Manager Maintenance-Object Repair Procedures
782 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
OLS Recycle Test (#126)
This test is destructive.
This test removes power from the specified carrier and causes every circuit pack in the recycled
carrier to be removed and inserted. These actions cause every call originating from or
terminating to circuit packs in this carrier to be dropped. The pair of OLSs in the specified
carrier is recycled. Both OLSs in the carrier are turned off for 2 seconds and then back on
again. After the OLSs have been turned back on, the test queries a PN’s Maintenance circuit
pack for the status of the pair of OLSs in the specified carrier. If both OLSs are on and
functioning, then the test passes. If both OLSs are not on and functioning, the test fails, and
BOTH OLSs are turned off.
Table 267: Test #126 OLS Recycle Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1366 ABRT Indicates that the active Tone-Clock for the PN is in requested carrier.
1. If duplicated Tone-Clock boards or IPSIs exist, useset tone-clock
to switch Tone-Clocks, otherwise the power cannot be cycled.
2. If the switch succeeds, rerun the test.
1367 ABRT Indicates that the active Expansion Interface link for the PN is in requested
carrier.
1. If duplicated EIs exist, use reset pnc interchange to switch EIs,
otherwise the power cannot be cycled.
2. If the switch succeeds, rerun the test.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2029,
2319,
2320,
2500
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.