TONE-PT (Tone Generator)
Issue 1 June 2005 2359
Notes:
Except in EPNs containing more than one IPSI or Tone-Clock circuit pack, replacing an IPSI or
Tone-Clock circuit pack is a service disrupting procedure. The test should be run several times
with more than one failure before the replacement policy specified in the following notes is
executed. Use the procedure described in Replacing the IPSI or Tone-Clock Circuit Pack
on
page 2337.
2000 ABRT Response to the test request was not received within the allowable
time period. System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1 (a
) FAIL DTMF generation failed for the active tone generator.
105 (a
) FAIL Generation of 440-Hz failed.
109 (a
) FAIL Generation of 2225-Hz failed.
110 (b
) FAIL Generation of 404-Hz level invalid.
111 (b
) FAIL Generation of 1004-Hz low level invalid.
112 (b
) FAIL Generation of 1004-Hz high level invalid.
113 (b
) FAIL Generation of 2804-Hz level invalid.
115 (b
, c) FAIL Generation of digital count sequence invalid.
120 (a
) FAIL Generation of quiet tone failed.
1044 (a
) FAIL DTMF generation failed to generate Digit 1 for the standby tone
generator.
1045 (a
) FAIL DTMF generation failed to generate Digit 5 for the standby tone
generator.
1046 (a
) FAIL DTMF generation failed to generate Digit 9 for the standby tone
generator.
1047 (a
) FAIL DTMF generation failed to generate Digit D for the standby tone
generator.
PASS The tone generation facility is able to generate and transmit all the
tones.
Table 843: Test #40 Tone Generator Transmission Test (continued)
Error
Code
Test
Result
Description / Recommendation