Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
2466 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Response to the test was not received within the allowable time period.
This may be due to hyperactivity. Error Type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service, and one or
more of the following symptoms may be exhibited.
1. The UDS1-BD tests (such as Tests #138 and #139) are aborting with
Error Code 2000.
2. The tests run on the ports of this circuit pack are returning a no-board
result.
3. A busyout or a release command has no effect on the test results.
4. A list config shows that the circuit pack and its ports are properly
installed.
When hyperactivity occurs, the circuit pack is isolated from the system, and
all of its trunks are placed into the out-of-service state. The system will try
to restore the circuit pack within 15 minutes. When no faults are detected
for 15 minutes, the UDS1 interface circuit pack is restored to normal
operation. Every trunk for the UDS1 interface circuit pack is then returned
to the in-service state. Hyperactivity is often caused by the associated
facility. In such a case, faults (such as slips, misframes, or blue alarms)
would be entered in the error log. In addition, many hardware errors would
be logged against the associated trunk circuits. If the facility is OK and the
error occurs again after 15 minutes, replace the circuit pack.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
PASS The One-Way Span test has successfully began transmitting a framed
3-in-24 test pattern. The runs until the system technician enters test
ds1-loop location end-loopback/span-test or release board
location.
Table 872: Test #1214 One-Way Span Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4