Communication Manager Maintenance-Object Repair Procedures
2080 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
104 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 4.
1. Perform the Fiber link fault isolation
procedure in Maintenance
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 513, replace the
SNI being tested. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. To view SNI-PEER errors, use display errors
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 513, replace the
SNI in slot 4. Replacing an SNI may be service interrupting.
SeeSNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. Retry the command.
105 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 5.
1. Perform the Fiber link fault isolation
procedure in Maintenance
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 769, replace the
SNI being tested. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. To view SNI-PEER errors, use display errors
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 769, replace the
SNI in slot 5. Replacing an SNI may be service interrupting. See
SNI-BD (SNI Circuit Pack)
on page 2046 for the procedure for
replacing an SNI. Retry the command.
Table 752: TEST #759 Configuration Audit (continued)
Error
Code
Test
Result
Description / Recommendation