TIE-DS1 (DS1 Tie Trunk)
Issue 1 June 2005 2285
FAIL Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface circuit pack or media module and switch
software are consistent. If the trunk is busied out, the test does not run but
returns a PASS. To verify that the trunk is in-service:
1. Enter status trunk to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is
out-of-service, continue to step 2.
2. Enter release trunk to put the trunk back into in-service.
3. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board’s translations are correct. Use list
configuration, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. If
not, check that there is a valid board inserted.
Table 817: Test #36 Port Audit and Update Test (continued)