Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Denial Event Tables
Issue 1 June 2005 183
1083 Add/Rmv skill denied Add/Remove Agent Skills. Possible causes:
could not get station ID
too many admin users or
save-translations in progress
data already locked, maybe translations
are being saved or SAT user is changing
agent data
1084 DCS link down Remote user activation of call forward -
Distributed Communication System (DCS) link not
up.
1085 PMS response timeout Property Management System failed to respond
to maid status in the 4 seconds allowed.
1086 MFC no answer timeout MultiFrequency Compelled (MFC) call circuit
congestion. No answer timeout from MFC call.
1087 MFC no answer timeout MultiFrequency Compelled call circuit congestion.
No answer timeout. Might be bad trunk or no
Touch Tone Receiver (TTR) available at remote
end, for example.
1088 No answer timeout MultiFrequency Compelled call circuit congestion.
No answer timeout. Might be bad trunk or no
Touch Tone Receiver (TTR) available at remote
end, for example.
1089 MFC no answer timeout MultiFrequency Compelled call circuit congestion.
No answer timeout. Might be bad trunk or no
Touch Tone Receiver (TTR) available at remote
end, for example.
1090 T302 intercept timeout T302 interdigit timer timeout.
1091 Max Paste users Pasting The maximum allowable stations are currently
using PC Application Software Exchange
(PASTE). Wait and try again.
1092 Announcement unavailable Might be announcement is busy, or
announcement is not present on board.
1093 Announcement memory exh Announcement is dropped, announcement
memory is exhausted.
1094 Permanent Seizure Direct Inward Dialing trunk origination. Digit
timeout with no digits dialed. Permanent incoming
seizure treatment is to give reorder.
1095 QSIG Call Offer timeout QSIG Call Offer encountered timeout of 1 minute
path retention timer.
1096 Wakeup time unavailable Collecting digits for “room wakeup by tones”
feature. Cannot do a wakeup for the specified
time.
1097 MFC No Answer timeout MFC call circuit congestion. No answer timeout.
Might be bad trunk or no Touch Tone Receiver
(TTR) available at remote end, for example.
Table 48: Call Process denial events (1001 - 1172) (continued)
Event
Type
Event Description, as it
appears on the event log
Explanation Event
Data 1
Event Data 2
7 of 13