Communication Manager Maintenance-Object Repair Procedures
1604 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Control Channel Looparound Test (#52)
This test queries the Media Module for its Media Module vintage to verify angel communication.
Table 590: Test #52 Control Channel Looparound Test
Error
Code
Test
Result
Description/ Recommendation
None
2100
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The Media Module failed to return the Media Module code or vintage.
1. Retry the command a maximum of 5 times.
2. If the problem continues, replace the Media Module.
PASS Communication with this Media Module is successful.
Any NO
BOARD
The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list
config and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout
board location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
If this is not the case, check to ensure that there is a valid board
inserted.