S-SYN-PT (Speech Synthesis Port)
Issue 1 June 2005 1991
Speech Synthesis Parameter Update Test (#169)
This test updates the dual-tone multifrequency (DTMF) interdigit time-out parameter used by
the Speech Synthesis circuit pack so that it is consistent with that specified by the server.
Table 735: TEST #169 Speech Synthesis Parameter Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call and therefore unavailable for certain tests. Wait
until the port is idle (amber LED is off) before retesting.
1. If the port is idle, retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL An internal system error has occurred.
PASS The DTMF interdigit time-out parameter has been updated. User-reported
troubles should be investigated using other tests and by verifying that other
ports on this circuit pack are working correctly.