Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
VC-DSPPT
Issue 1 June 2005 2517
1002 ABRT The system could not allocate time slots for the test. The traffic load on the
system is very high, or time slots may be out-of-service due to TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a Tone Detector for the test. The system is
oversized for the number of Tone Detectors present, or some Tone
Detectors are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to
5 times.
1004 ABRT The port is seized by a user for a valid call. Use status station for the
station associated with this port and determine whether the port is available
for testing.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test was not received from the VC-BD circuit pack within
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the port by using
busyout port location and reset port location.
2. If this result occurs again, replace the circuit pack.
2012 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2103 ABRT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
0–3 FAIL The TDM Loop-Around test failed.
1. Replace circuit pack.
Table 893: Test #1104 VC DSPPT Local TDM Loop-Back Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3