Communication Manager Maintenance-Object Repair Procedures
380 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call. Use display port location to determine the
station extension, attendant number, or trunk group/member number of the
port. Use status station, status attendant, or status trunk to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABRT The port received an EXT-DEV failure during the test. The test has been
aborted.
1. Before retesting, enter test external-device-alarm port
location to determine whether the port is reporting an EXT-DEV
failure.
2. If the port has no EXT-DEV failures, retry the command at 1-minute
intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The port’s battery feed chip is unable to supply sufficient power to sense
the external device alarm. This may occur when the test is performed at
the same time that the external device contact closure occurs.
1. Before retesting, enter test external-device-alarm port
location to determine whether the port is reporting an EXT-DEV
failure. Wait until the port has no EXT-DEV failures before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
PASS The port’s battery feed chip is able to provide power to the external device
alarm to detect contact closure.
Table 110: Test #35 Battery Feed Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3