Communication Manager Maintenance-Object Repair Procedures
542 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
t. Error Type 3329: The on-board LANHO chip is insane, possibly due to a problem in
packet-bus arbitration, the transmission line frame, or the circuit pack itself. The circuit pack
cannot talk to the packet bus.
If the packet bus is alarmed:
1. Resolve any PKT-BUS errors. The probability of this error being related to a packet-bus
problem increases with the number of other circuit packs using the bus that are also
showing this error.
If the packet bus is not alarmed:
2. Reset the circuit pack (reset board location).
3. If the problem persists, replace the ATM-EI circuit pack.
If the system has a duplicated PNC, and the in-line error received is from an active ATM-EI,
the system switches to the standby PNC.
!
CAUTION:
CAUTION: If the system does not have duplicated PNC, services to the PN could be
disrupted.
u. Error Types 3585 and 3586: (Major board alarm) A failure of critical components involved
in the operation of the circuit pack, and the switch can no longer recognize the circuit pack.
If the system has a duplicated PNC and the in-line error received is from an active ATM-EI,
the system switches to standby PNC.
!
CAUTION:
CAUTION: If the system does not have duplicated PNC, services to the PN could be
disrupted.
Error Type 3585
Aux Data (Error Type 3585 only):
Aux
Data
Description
1 ATM framer failure
2 NCE failed (only from ATM-EIs in PN)
4 TDM_PLD_FAILED
5 DSP_ALL FAILED
6 Receive Network Processor (RNP) failure
7 Transmit Network Processor (TNP) failure
8 MEMORY read/write failure