ADX16D-P (16-Port AUDIX Digital Port)
Issue 1 June 2005 359
Table 97: Test #9 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
1 ABRT During testing of the primary information channel, system resources may
not have been available. Also, the port may have been busy during the test.
1. Check the port status.
2. Use display port location to determine the voice port extension
of the port. Use status station to determine the service state of the
port. If the port is active, it is unavailable for this test. Wait until the port
is idle.
3. Retry the command at 1-minute intervals up to 5 times.
2 ABRT System resources may not have been available, or the port may have been
busy during the test.
1. Verify that the port’s status is idle.
2. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be active.
1. Use display port location to determine the voice port extension
of the port. Use status station to determine the service state of the
port. If the port is active, it is unavailable for certain tests. Refer to
“Status” commands in Maintenance SAT Commands
in Maintenance
Commands Reference (03-300191), for a full description of every
possible state. Wait until the port is idle before testing.
2. If the port’s status is idle, retry the command at 1-minute intervals up to
5 times.
1001 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.