MG-DS1 (DS1 Interface Media Module)
Issue 1 June 2005 1639
Translation Update Test (#146)
The Translation Update Test sends the circuit-pack-level information specified by System
Administration to the MM710 Interface Media Module. Translation includes the following data
administered for a MM710 Interface Media Module (see output of display ds1 location
command): DS1 Link Length between two DS1 endpoints, Synchronization Source Control, All
Zero Suppression, Framing Mode, Signaling Mode, Time Slot Number of 697-Hz Tone, Time
Slot Number of 700-Hz Tone, etc.
Table 600: TEST #146 Translation Update Test
Error
Code
Test
Result
Description/ Recommendation
ABRT Internal system error
1. Retry the command at 1-minute interval s a maximum of 5 times.
FAIL Internal system software error.
1. Enter the display ds1 location command to verify the MM710
Interface Media Module translation.
PASS Translation data has been downloaded to the MM710 Interface Media
Module successfully.
Any NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board
is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
location command to administer the MM710 interface if it is not
already administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then enter
the busyout board location command.
4. Enter the reset board location command.
5. Enter the release board location command.
6. Enter the test board location long command.
This should re-establish the linkage between the internal ID and the port.