VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 1 June 2005 2495
PPE/LANBIC Receive Parity Error Counter
Test (#595)
This test is nondestructive. When the VAL circuit pack detects a parity error with a received
frame, it increments the PPE/LANBIC Receive Parity error counter. This test reads and clears
the counter, and can verify repair of the problem.
Errors can indicate a problem with:
This circuit pack
A packet bus
Another circuit pack on the bus
Table 882: Test #595 PPE/LANBIC Receive Parity Error Counter Test
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board
location).
3. If the problem persists, replace the circuit pack.
2100 ABRT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1–10 FAIL Circuit pack detects parity errors. The Error Code indicates the value of the
on-board error counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, execute the Packet Interface test (#598)
(test board location).
3. If Packet Interface test (#598) fails, see repair procedures for Test
#598.
PASS Circuit pack detects no errors.