M/T-DIG (Maintenance/Test Digital Port)
Issue 1 June 2005 1719
1019 ABRT An ISDN test call is in progress using this Maintenance/Test circuit pack.
The Maintenance/Test circuit pack cannot perform a self-test on one of its
digital ports while an ISDN test call is using either of the digital ports. Use
list isdn-testcall to determine which call is using the port, from
the M/T Port column. Wait for the test call to complete as indicated in the
Start Time and Duration fields, or abort the test call with clear
isdn-testcall grp#/mem#, where grp#/mem# is determined from
the B-channel field of list isdn-testcall.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
1138 ABRT This test does not run on port 3 of the Maintenance/Test circuit pack. This
test will only run on port 2. Look at the results of the Digital Port Sanity
test for port 2.
1. Run the command again for port 2 using test port location
(02) or test port location (02) l.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals up to 5 times.
50 FAIL The switch was unable to communicate with the port circuitry used for
digital trunk testing.
100 FAIL Data was not sent from port 2 to port 3 successfully in asynchronous
mode.
1. Reset the circuit pack using busyout board location, reset
board location, and release board location.
2. Test the port again using test port location (02) l.
3. If the test fails again, replace the circuit pack.
Table 636: Test #565 Digital Port Sanity Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3