EMG-XFER (Emergency Transfer)
Issue 1 June 2005 1135
Notes:
a. Error Type 1 indicates that the Emergency Transfer switch located on the Processor circuit
pack is set to the manual ON position (up). When the Emergency Transfer switch is in this
position it generates a Major alarm.
b. Error Type 257 indicates that the Emergency Transfer switch located on the Processor
circuit pack is set to the manual OFF position (down). When the Emergency Transfer switch
is in this position it generates a Warning alarm.
System Technician-Demanded Tests: Descriptions and Error
Codes
Investigate tests in the order presented. By clearing error codes associated with the Cabinet
Query Test, you may also clear errors generated from other tests in the testing sequence.
Single Carrier System
Notes:
a. See CABINET (Cabinet Sensors)
on page 758 for a description of this test.
b. See EXT-DEV ADMIN? Y (External Device Alarm)
on page 1246 for a description of this
test.
c. See RING-GEN (Analog Ring Generator)
on page 1942 for a description of this test.
Table 387: Emergency Transfer System Technician-Demanded Tests
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Cabinet Query Test (#122) (a)XXND
Emergency Transfer Query Test (#124) X X ND
External Alarm Lead Query Test (#120) (b
)X XND
Analog Ring Generator Initialization Test
(#117) (c
)
XXND
Analog Ring Generator Query Test (#118) (c
)X X ND