Communication Manager Maintenance-Object Repair Procedures
720 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 243: Test #626 Signaling Link Status Test
Error
Code
Test
Result
Description / Recommendation
1139 ABRT The PN’s packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, use test port long location, and
review the results of the BRI Port Local LAN Loop Around test (#618) to
verify the repair.
1141 ABRT The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance
documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.
1187 ABRT The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station
via release station.
b. If this error type is present for BRI-PORT and BRI-SET, then release
the port via release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via release port location and run the
test again. If the error is present for BRI-SET only, then release the
circuit pack via release port location and run the test again.
If the error is present for both BRI-BD and BRI-PORT, then release
the circuit pack via release board location and run the test
again.
Note:
Note: When you release the circuit pack, you release every port
associated with it. If certain ports still need to be busied out,
use busyout port location to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1 of 2