Communication Manager Maintenance-Object Repair Procedures
968 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Dial Tone Test (#0)
Note:
Note: S8300 / G700: This test aborts with Error Code 1412.
This test attempts to seize a port and checks for the return of a dial tone.
Table 333: Test #0 Dial Tone Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the trunk group/member
number of the port. Use status trunk to determine the service state
of the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. Wait until the port is idle before
retesting.
2. If the port status is idle, then retry the command at 1-minute intervals up
to 5 times.
1001 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1004 ABRT The port has been seized by a user for a valid call. Use status trunk to
determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1018 ABRT Test has been disabled via administration.
1. The Maintenance Tests field must be y on the Trunk Group form for
this test to run. Use change trunk-group grp# to access the form.
Then change the entry in the Maintenance Tests? field on the form to
y.