Communication Manager Maintenance-Object Repair Procedures
1572 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 581: Test #57 Hybrid Circuit and Conference Circuit Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port
may be busy with a valid call.
1. Use display port location to determine the station extension
of the port. Use status station to determine the service state of
the port. If the port is in use, wait until the port is idle before retesting.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1001 ABRT System resources required to run this test were not available. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, repeat test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present or some
Tone Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension
of the port. Use status station to determine the service state of
the port. If the port is in use, wait until the port is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.