Communication Manager Maintenance-Object Repair Procedures
1696 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
M/T-ANL (Maintenance/Test Analog Port)
S8700 | 8710 / S8500
The Maintenance/Test analog port is port number 1 on the TN771D Maintenance/ Test circuit
pack. This port is used by the Automatic Transmission Measurement System (ATMS) as an
Originating Test Line (OTL) or Terminating Test Line (TTL) for test calls over analog trunks. For
more details, see Automatic Transmission Measurement System
in Maintenance Procedures
(03-300192). Figure 96
shows a typical ATMS configuration.
M/T-ANL maintenance ensures that the analog trunk’s testing function is operating correctly.
Although an M/T-ANL alarm can reduce service, it will not block service. To accurately measure
the performance and health of analog trunks, replace an alarmed TN771D when a new circuit
pack is available.
Figure 96: ATMS Tie Trunk Test Call
MO Name in
Alarm Log
Alarm
Level
Initial SAT Command to Run Full Name of MO
M/T-ANL MIN test port location l Maintenance/Test analog port
M/T-ANL WRN release port location Maintenance/Test analog port
Tie
Trunk
Facilities
Originating
Test Line
(OTL)
TN771
TDM Bus
Terminating
Test Line
(TTL)
TN771
TDM Bu
s
PBX originating
the test call
PBX terminating
the test call
Tie Trunk
Circuit Pack
Tie Trunk
Circuit Pack