Communication Manager Maintenance-Object Repair Procedures
1904 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1125 ABRT PPP Link is not in service.
1. Verify whether PPP link is in-service (status port location or
status link n).
2. If the PPP link is not in service, release the link (release link n or
release port location).
3. Repeat the test.
2100 ABRT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL PPP link is down.
1. Test the port (test port location long) to verify the SCOTCH
Synchronous Local Loop Around test (#1275) result.
2. If the test passes, wait for sessions to come up.
3. If the test fails, check the destination and other components in the
path (e.g., DS1 trunks).
4. If the destination and other components in the path are in-service and
the test still fails, execute busyout port location and release
port location, and repeat the test.
5. If the test still fails, reset the circuit pack (busyout board
location, reset board location, and release board
location). Repeat the test.
6. If the problem persists, replace the circuit pack.
PASS PPP link is up.
Table 696: Test #1279 PPP Link Status Inquiry Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2