Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
DID-DS1 (Direct Inward Dial Trunk)
Issue 1 June 2005 893
1000 ABRT System resources required for this test were not available. The port may
be busy with a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is active but the port is idle (no calls), check the error
log for Error Type #1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to
5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out of service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic
and the port status is idle, retry the command at 1-minute intervals up
to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Enter list measurements tone-receiver to display information
about the tone receivers.
2. Resolve any TTR-LEV errors.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a user for a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is idle, retry the command at 1-minute intervals up to
5 times.
Table 305: Test #7 Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4