ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005 631
Connection Audit Test (#50)
Nondestructive (in a sane switch environment).
The Connection Audit test updates TDM time slots. It sends network-update Control Channel
Message Set (CCMS) messages that tell the ATM-TRK circuit pack to listen to, talk to, or
disconnect particular time slots.
The test passes if software successfully sends the downlink network-update messages. It
aborts otherwise.
!
CAUTION:
CAUTION: Though normally nondestructive, this test could unintentionally tear down an
active call if the connection-manager software’s tables are corrupt.
Table 211: Test #50 Connection Audit Test
Error
Code
Test
Result
Description / Recommendation
None,
2100
ABRT System resources required for this test are not available.
1. Retry the command up to 5 times at 1-minute intervals.
1019 ABRT The test aborted because a test was already running on the port.
1. Retry the command up to 5 times at 1-minute intervals.
FAIL Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
1 of 2