Communication Manager Maintenance-Object Repair Procedures
722 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
This test is not executed for ASAI adjuncts because adjuncts do not support MIMs upon which
this test is based.
Table 244: Test #627 BRI Remote Loop Back
Error
Code
Test
Result
Description / Recommendation
1000 ABRT Could not seize the endpoint or B channels for test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABRT The endpoint’s MIMs Supported field is administered to “no.”
1. Use change station extension to change parameter only if the
endpoint documentation reflects support for ISDN-BRI Management
and Maintenance Procedures.
1113 ABRT The signaling link between the switch and the endpoint is down.
1. Use test port location long to clear any errors that prevent
establishment of the signaling link.
2. Examine the results of the Signaling Link Status test (#626) that is run
as part of this command. If this test aborts or fails, follow the repair
procedure for Test #626.
3. If the XID test (#628) continues to abort, escalate the problem.
1139 ABRT The PN’s packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute test port long location, and
review the results of the BRI Port Local LAN Loop Around test (#618)
to verify the repair.
1141 ABRT The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance
documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.