Communication Manager Maintenance-Object Repair Procedures
1452 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
maint/FE WRN Signaling channel has
been down for over 90
sec.
Consult ISDN-SGRP and/or
ISDN-LNK. Far-end signaling
channel may be busied out, or the
far-end switch may currently be
restarting.
WRN Repeated failure of far
end to respond to
messages.
Maintenance software will
periodically try to resend
messages. You can speed the
process with test trunk grp#/
mem# and/or test
signaling-group sig-grp#.
WRN The far-end trunk is
being tested.
Check status of the far-end switch.
Wait for testing to finish.
in-service None Normal operating state
1. ISDN-TRK alarms; alarms against other objects may also be present.
Table 520: Service States (continued)
Service State Alarm
1
Possible Cause Possible Solution
2 of 2
Table 521: DS1 ISDN Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test port location
1 (b
)AnyNone test port location
15 (c
) Any Audit and Update Test
(#36)
18 0 busyout trunk
grp#/mem#
release trunk grp#/mem#
19 (d
)0None
129 (e
)None WRNOFFtest port location
130 (f
)None WRNONtest port location
257 (g
)AnyNone test port location
1 of 2