Server Alarms
98 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
This test runs an off-hook test for the modem attached to the USB port on the server. The test
sends an ATH1 string to check that a line is connected to the modem. The following errors can
be detected:
Reset USB Test
This test is destructive.
This test causes the modem to be reset, even if the modem is in use. Although no failures are
produced by this test, the following error can be detected:
Back to: Hardware MOs
Server-related alarms
Table 29: TEST Off-Hook Test
Error Code Test
Result
Description / Recommendation
Modem in
use, try again
later
ABRT Some other application is currently using the modem. Try again
later.
Could not
open USB
port
ABRT System error: An attempt to open the USB device failed. Try again
later
Read error,
could not run
test
ABRT After the ATZ is sent, a read of the USB device is done. If the read
fails, a probable system error aborted the test. Try again.
Modem
Off-Hook test
failed
FAIL Modem Off-Hook test failed: The modem did not return an “OK”
string within a 15-second interval. This indicates that dial tone was
not detected in the allotted time.
Table 30: TEST Reset USB
Error
Code
Test
Result
Description / Recommendation
Could not
open USB port
ABRT System error: An attempt to open the USB device failed. Try
again later.