M/T-DIG (Maintenance/Test Digital Port)
Issue 1 June 2005 1721
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test digital port maintenance software and call
processing agree on the on-/off-hook status of the Maintenance/Test digital port.
Table 637: Test #566 Hook State Inquiry
Error
Code
Test
Result
Description / Recommendation
1 ABRT Switch hook audit timed out. No response was received from the circuit
pack for information about the switch hook state.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, replace the circuit pack and repeat the
test.
3. If the test continues to abort, escalate the problem.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Any FAIL Internal system error. This test should never return a failure.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, reset the circuit pack using busyout
board location, reset board location, and release
board location.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to fail, escalate the problem.
PASS Call processing and Maintenance/Test digital port maintenance software
agree on the Maintenance/Test digital port hook state.