WAE-PORT (Wideband Access Endpoint Port)
Issue 1 June 2005 2535
Conference Circuit Test (#7)
Note:
Note: G700: On the G700, this test aborts with Error Code 1412.
The Conference Circuit test verifies that the NPE channel for the port being tested can correctly
perform the conferencing function. The NPE is instructed to listen to several different tones and
conference the tones together. The resulting signal is then measured by a Tone Detector port. If
the level of the tone is within a certain range, the test passes.
1004 ABRT The port has been seized by a user for a valid call. Use status
access-endpoint extension to determine when the port is available
for testing. The port is available when it is in the in-service/idle state.
1. Retry the command at 1-minute intervals up to 5 times.
1020 ABRT The test did not run because of a previously existing error on the specific
port or a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
G700:
1412
ABRT On the G700, this test aborts with Error Code 1412.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
1. Investigate user-reported troubles on this port using other port tests
and by examining the terminal adapter or external wiring.
Table 901: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2