Communication Manager Maintenance-Object Repair Procedures
1172 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
102 FAIL 2225-Hz Modem Answer Tone was not detected correctly. This
impacts call-classification operation.
1. Run the short test sequence via test port location sh r
1.
2. If the problem persists, the system can still operate properly but
capacity is reduced. In order to restore performance to normal,
replace the circuit pack containing the defective port. Follow the
procedures described in TONE-BD (Tone-Clock Circuit)
on
page 2327 for replacing a Tone-Clock circuit pack.
130 FAIL Forward or Backward MFC signals were not correctly generated or
detected. This will impact MFC calls.
1. Run the short test sequence via test port location sh r
1.
2. If the problem persists, the system can still operate properly but
capacity will be reduced. In order to restore performance to
normal, replace the TN2182/TN2312AP circuit pack containing the
defective ETR-PT. Follow the procedures described in TONE-BD
(Tone-Clock Circuit) on page 2327 for replacing a Tone-Clock
circuit pack.
PASS Tone detection verification is successful. The ETR port is able to detect/
generate every necessary tone.
Table 403: Test #42 Tone Detection Verification Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3