Communication Manager Maintenance-Object Repair Procedures
446 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Enter list
configuration, and resolve any problems.
2. If the board is correctly inserted, enter busy board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the link between the internal ID and the port. If
not, verify that a valid board is inserted.