Communication Manager Maintenance-Object Repair Procedures
960 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Port Audit and Update Test (#36)
This test sends port-level translation data from switch processor to the DS1 Interface circuit
pack to assure that a trunk’s translations are correct. Translation updates include the following
data: trunk type (in/out), dial type, timing parameters, and signaling bits enabled. The port audit
operation verifies the consistency of the current state of trunk kept in the DS1 Interface circuit
pack and in switch software.
FAIL The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated by using other port tests and by
examining station, trunk, or external wiring.
Table 329: Test #7 Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3
Table 330: Test #36 Port Audit and Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
2100 ABRT Could not allocate the necessary system resources to run this test.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2