Communication Manager Maintenance-Object Repair Procedures
644 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
ATM Board Time Of Day Update (#1261)
The nondestructive ATM-TOD-UPD test updates the system time used by the ATM-TRK circuit
pack for SDH/SONET performance monitoring and synchronizes the ATM-TRK circuit pack with
the S8700 Multi-Connect system’s clock. This test is run during initialization, scheduled
maintenance, and craft long test.
Table 219: ATM Board Time Of Day Update (#1261)
Error
Code
Test
Result
Description / Recommendation
2031 FAIL The attempt to send the message to the ATM-TRK circuit pack was not
successful.
2500 FAIL Internal system error. Did not send the time-of-day information to the
board.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test aborts with the same error code, escalate the problem.
PASS The ATM-TRK circuit pack is successfully updated with system time.
1. If status port-network still indicates that this link is down, one or
both of the ATM-TRK circuit packs may have been busied out.
2. If the link still does not come up, reset one or both ATM-TRK circuit
packs on the link.
0
NO
BOARD
No board detected.
1. Check the error log for wrong board (Error 125) or no board (Error
131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check
for hyperactivity (Error 1538). If hyperactive, use reset board
location.
3. Run the test again. If it fails, the board could be bad. Replace the
board and retest.