Communication Manager Maintenance-Object Repair Procedures
1566 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1018 ABRT Test disabled by administration. This only applies to analog stations. The
default for this field is y, so you may want to determine why it was turned
off on this station.
1. To enable the test for the particular analog station being tested, enter
change station extension and set the Test field on the Station
screen to y.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2020 ABRT The test did not run due to an already existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2100 ABRT System resources required to run this test are not available. This could be
due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL This test can fail due to on-board or off-board problems. Off-board
problems of concern include EXP-PN, EXP-INTF, or RMC-ENV faults,
TDM-BUS faults, and faults associated with the tone detectors/tone
generators. Clear every off-board problem before replacing the board.
Keep in mind that a TDM-BUS problem is usually the result of a faulty
board connected to the backplane or bent pins on the backplane.
1. Resolve any EXP-PN, EXP-INTF, or RMC-ENV errors.
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD and/or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared.
Replace the board only if the test fails.
PASS The port uses its allocated time slots correctly. Investigate user-reported
troubles on this port using other port tests and by examining station, trunk,
or external wiring.
Table 578: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4