VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 1 June 2005 2501
Link Status Test (#601)
This nondestructive test determines the state of the call-control signaling link for VALs. If the
signaling link is physically connected, the test sends a test frame over the link and checks for a
response. The test passes only if both the signaling link is connected and the test frame is
successfully transmitted.
A failure can indicate a problem with:
this circuit pack
the packet bus
the Packet Interface circuit pack
Table 887: Test #601 Link Status Test
Error
Code
Test
Result
Description / Recommendation
1125 ABRT RSCL link or VAL board not in service.
1. Release the board.
2. Repeat the test.
3. Escalate if the problem persists.
2012 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
2100 ABRT Internal system error.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
2 FAIL The RSCL control link disconnected.
1. Retry command at 1-minute intervals up to 5 times.
2. If the test continues to fail, execute the Packet Interface test (#598)
(test board location) to see if the problem is in the circuit pack.
If the Packet Interface test (#598) fails, see Packet Interface Test
(#598) repair procedures.
If the Packet Interface test (#598) passes, see Packet Interface Test
(#598) and Packet bus repair procedures.
1 of 2