BRI-SET, Various Adjuncts
Issue 1 June 2005 723
1187 ABRT The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,
BRI-PORT, or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station
via the release station
b. If this error type is present for BRI-PORT and BRI-SET, then release
the port via release port location and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via the release port location and run
the test again. If the error is present for both BRI-BD and
BRI-PORT, then release the circuit pack via release board
location and run the test again. If the error is present for
BRI-SET only, then release the circuit pack via release port
location and run the test again.
Note:
Note: When you release the circuit pack, you release every port
associated with it. If certain ports still need to be busied out,
use busyout port location to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2068 ABRT The endpoint has rejected the switch sent application message. This
indicates that the endpoint does not support the ISDN-BRI Management
and Maintenance Procedure for Loop Back testing.
1. Use change station extension and set the MIMs Supported
field to n.
Table 244: Test #627 BRI Remote Loop Back (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3