Communication Manager Maintenance-Object Repair Procedures
506 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
ASAI-RES (TN800 reserve slot)
Error log entries and tests also apply to E-DIG-RES.
S8700 | 8710 / S8500
There are no tests associated with these MOs. Both the test board and busyout board
commands abort when either is attempted on a reserved slot. An error message indicates the
slot is associated with the circuit pack that the TN800 is emulating, but the requested operation
is not valid.
The TN800 MAPD (Multi-Application Platform) circuit pack connects to the switch through a
single slot in the backplane. The number of slots occupied by the MAPD pack is supplied by the
board when inserted. The TN800 in R5EM is three slots wide. The TN800 requires 2 reserve
slots to its left. The reserve (blank) slots are to left of the functional slot and are place holders
on the switch, and do not have any interaction with the switch.
Each instance of these MOs represents a reserve slot associated with respective circuit pack
mode in which the MAPD is working.
MO Name in
Alarm Log
Alarm
Level
Initial Command to Run Full Name of MO
ASAI-RES NONE NONE TN800 ASAI reserve slot
E-DIG-RE NONE NONE TN800 DIG reserve slot