ANL-16-L (16-Port Analog Line)
Issue 1 June 2005 389
1018 ABRT The test has been disabled by administration. The default for the Test field
on the station screen is y. Determine why this field has been set to “no” on
this station (this may be due to the ringing application Test #48, that can
be customer or terminal disturbing.
1. To enable the test for a particular station being tested, enter change
station extension and set the Test field on the station screen to
y.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run test are not available. This could be due
to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL This test can fail due to either on- or off-board problems. Off-board
problems include EXP-PN and EXP-INTF faults, (
S8700 IP: RMC-ENV
faults), TDM-BUS faults, and faults associated with the Tone Detectors/
Tone Generators. Clear every off-board problem before replacing the
board. A TDM-BUS problem is usually the result of a faulty board
connected to the backplane, or bent pins on the backplane.
1. Resolve any EXP-PN and EXP-INTF errors.
S8700 IP: Resolve any RMC-ENV errors.
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared.
Replace the board only if the test fails.
PASS The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests, by examining
station wiring, or by examining the station.
Table 113: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4