1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to
5 times.
1004 ABRT The port was seized by a valid call during the test.
1. Use display port location to determine the station extension or
attendant number of the port.
2. Use status station or status attendant to determine the
service state of the port.
3. If the service state indicates that the port is in use, then the port is
unavailable for certain tests. Wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is plugged in and
the port is not busied out.
1020 ABRT Test disabled by background testing. Use status station to determine
when the station is available for testing.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
1
2
FAIL The Network Processing Element (NPE) of the tested port is transmitting in
error. This causes noisy and unreliable connections.
Error code 1 = Crosstalk test failed on the primary channel.
Error code 2 = Crosstalk test failed on the secondary channel.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
1. To ensure that this is not an intermittent problem, repeat this test up to
10 times.
2. If complaints persist, examine the station, connections, and wiring.
Table 383: Test #9 Digital Line NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2