Communication Manager Maintenance-Object Repair Procedures
1938 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 712: Test #17 Station (Digital) Audits Test
Error
Code
Test
Result
Description / Recommendation
1 ABRT Switchhook audit timed out.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
2 ABRT ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
3 ABRT The EPF has detected an overcurrent condition.
1. Use test WRN long. If Test #11 passes, then the EPF condition
was cleared. Rerun the short test sequence. If Test #11 does not pass,
follow the repair procedures described for Test #11.
2. Look for Error Type 769 logged against RDIG-STA, and follow the
procedures in the associated footnote. If any additional problems are
found, rerun the test.
4 ABRT Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals up to 5 times.
5 ABRT Ringer update aborted due to station being in ready-for-service or
out-of-service state.
6 ABRT This port may have been busied out by a system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error is present, use release station to release the port.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.