Communication Manager Maintenance-Object Repair Procedures
498 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Figure 24: BRI Port Local LAN Loop-Around Path
Table 151: Test #618 BRI Port Local LAN Looparound
Error
Code
Test
Result
Description / Recommendation
1015 ABRT The port is not in the out-of-service state.
1. Display the Port Status screen using status bri-port location
to determine which stations or adjuncts are on this port.
2. Use the extension shown on this screen in status station to
determine whether the station or adjunct is active.
3. If the port is active, wait until it is idle, and use busyout port
location to place it in the out-of-service state and repeat this test.
!
WARNING:
WARNING: Since the busyout command is destructive, using this
command prior to the port being idle causes every
transaction associated with the ASAI on the port to be torn
down. Note that 3
rd
-party calls established by an ASAI
adjunct remain connected even though the port is taken
out-of-service.
1 of 2
BRI LINE
CIRCUIT
PACK
PACKET
INTERFACE
PACKET BUS
.
.
.
.
. . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
. . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
. . . .