Communication Manager Maintenance-Object Repair Procedures
1764 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
● EPF inquiry: The status of the Electronic Power Feed is sent uplink. EPF is not used for
data modules.
● ID Request: A request is made to the data module for its status. The data module sends its
configuration information and health information back. This information is checked and a
pass/fail result is provided.
● Ringer Update: This updates the data module’s ringer state according to processor
records.
● Translation Update: This is a message normally used with digital stations to refresh the
default value that causes the station to send touch tones only in the primary information
channel. This test is not used with data modules.
Table 653: Test #17 Data Module Audits Test
Error
Code
Test
Result
Description / Recommendation
1 ABRT Switchhook audit timed out.
1. Verify the data module is connected to the PBX and repeat the test.
2. If the test aborts, replace the data module and repeat the test.
3. If the test continues to abort, replace the circuit pack and repeat the
test.
2 ABRT ID request fails, health bit is defective, or no response from on-board
microprocessor.
1. Verify that the correct data module type (PDM versus TDM) is
administered.
2. If the test aborts, replace the data module and repeat the test.
3. If the test aborts, replace the circuit pack and repeat the test.
3 ABRT No response from EPF audit.
4 ABRT Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals up to 5 times.
1 of 2