Communication Manager Maintenance-Object Repair Procedures
384 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
ANL-16-L (16-Port Analog Line)
S8700 | 8710 / S8500
The circuit packs listed below provide 16 analog line ports for single-line voice terminals. The
table below indicates which circuit packs are equipped with lightning protection (for
off-premises, out-of -building stations), and which ones support the neon message waiting lamp
feature.
S8700 | 8710 / S8500
These circuit packs provide 16 ports for analog voice terminals. The TN746, TN468, and TN749
support only single-line, on-premises/in-building, analog voice terminals, and not off-premises
stations, since these circuit packs are not equipped with lightning protection. The TN746B,
TN2144, TN2149, and TN468B support both on-premises and off-premises (that is,
out-of-building) analog voice terminals. The TN468, TN468B, TN479, TN2135, TN2144, and
TN2149 do NOT support the neon message waiting feature.
No maintenance of the terminal connected to the 16-Port Neon Analog Line circuit pack is
performed, except to determine whether or not the terminal is connected. Failures of the neon
message waiting lamp power and the common ringing application circuitry are reported as part
of common port circuit pack errors; see errors 1281 and 1793 in XXX-BD (Common Port Circuit
Pack/Media Module) on page 2539.
MO Name in Alarm Log Alarm
Level
Initial Command to Run Full Name of MO
ANL-16-L MIN test port location l 16-Port Analog Line
ANL-16-L WRN test port location sh 16-Port Analog Line
16-Port Analog Line Circuit Packs
Circuit Pack Off- Premises Neon
TN468B y
TN479
TN746 y
TN746B y y
TN2135 y
TN2144 y
TN2149 y
TN2180 y