Communication Manager Maintenance-Object Repair Procedures
1472 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2040 ABRT Internal system error.
1. Follow recommendations for ABORT code 2012.
2041 ABRT The call has timed out, perhaps because of a lack of system resources.
Follow recommendations for ABORT code 2035.
2066 ABRT Could not establish test call.
1. Retry the command at 1-minute intervals up to 5 times.
2067 ABRT The call has timed out, perhaps because of a lack of system resources.
1. Follow recommendations for ABORT code 2035.
2074 ABRT Bit and Block Error query failed.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, there may be a serious internal problem
with M/T-DIG (Maintenance/Test Digital Port). If this is the case, seeM/
T-DIG (Maintenance/Test Digital Port) on page 1709.
2075 ABRT Internal system error. Follow recommendations for ABORT code 2012.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2104 ABRT Call dropped or could not be originated.
1. Make sure service is provisioned by the network.
2. Check the administration of the far-end test line extension on the
Trunk Group Administration form.
3. Check the administration of the Testcall BCC (Bearer Capability Class)
on the Trunk Group Administration form.
4. Check the reason for termination with status isdn-testcall.
5. For further instructions see Troubleshooting ISDN-PRI test calls
in
Maintenance Procedures (03-300192).
6. Try the test again.
2201,
2202,
2203,
2204,
2205
ABRT Internal system error. Follow recommendations for ABORT code 2012.
Table 530: Test #258 ISDN Test Call (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 6