Communication Manager Maintenance-Object Repair Procedures
1358 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 1: the circuit pack has been removed from the system or is not fully
administered. The alarm is logged about 15 minutes after the circuit pack has been
removed, or 11 minutes after the SAKI test (#53) fails.
To be fully administered, an IPMEDPRO circuit pack must meet four conditions:
● Have an entry in the circuit pack screen (change circuit-pack)
● Have the MedPro IP address administered (change node-names ip)
● Be enabled (change ip-interface)
● Be physically inserted into the correct slot
If the circuit pack has an entry on the circuit pack screen and any of the other conditions are
NOT met, a MINOR alarm is logged. To resolve the error:
2561 (n
) Ping error
(#1379)
MIN OFF
2817 (o
) Any Ethernet
Hardware Query
test (#1405)
MIN ON
3073 (p
) Any Circuit pack reset
test (#53)
MIN ON
3329 (q
) Any Duplicate
network IP
Address detected
MIN OFF
3585 (r
) 1 or 2 Verify NIC option
test (#1511)
MIN OFF
3841(s
) None Inconsistent
downlink
3841(t
) 4283 RTCP Monitor
Server error
3999 (u
) Any None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
2. Minor alarms on this MO may be downgraded to warning alarms based on values set in set options.
Table 474: TN2302 IPMEDPRO Circuit Pack Maintenance Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value