Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1920 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
e. Error Type 513: Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this disturbs the customer or the terminal equipment, disable it by setting
the Tests field on the change station extension screen to n. On some software
releases, this will also disable Tests #7 and 35.
f. Error Type 2817: the endpoint caused a large number of control channel messages to be
sent to the switch within a short period of time (50 or more CCMS uplinks within 10
seconds). The station will be taken out-of-service for 30 seconds due to the hyperactivity.
This may be completely normal during heavy traffic periods.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one
test may also clear errors generated from other tests in the sequence.
Battery Feed Test (or Port Diagnostic test) (#35)
The battery feed chip provides power to the telephone equipment, signaling, rotary dial pulsing,
transmission, and balance. This test checks the signaling and switchhook capabilities of the
battery feed chip by terminating the port, applying battery and detecting the resulting current.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Battery Feed test (#35) X X ND
Station Present test (#48) X X ND
Station Status and Translation Audits and Updates test (#36) X X ND
Table 705: Test #35 Battery Feed Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3