Communication Manager Maintenance-Object Repair Procedures
924 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
DIG-LINE (Digital Line)
S8700 | 8710 / S8500 / S8300
DIG-LINE monitors and tests ports on digital line circuit packs or digital line media modules and
on hardware administered as a digital station on those ports. These include stations with only a
digital phone and stations with a digital phone linked to a data module.
S8700 | 8710 / S8500
Standalone data modules, and data adaptors in standalone mode, are covered by PDMODULE
(Processor Data Module) on page 1751. Circuit pack-level maintenance is covered by DIG-BD
(Digital Line Circuit Pack) on page 915, the strategy for which is described in XXX-BD
(Common Port Circuit Pack/Media Module) on page 2539.
The following circuit packs support digital lines:
MO Name in
Alarm Log
Alarm
Level
Initial SAT Command to Run Full Name of MO
DIG-LINE MIN test port location l Digital Line
DIG-LINE WRN test port location sh Digital Line
Table 317: Digital Line Circuit Packs
Code Port
s
Type Compandin
g
Endpoints
TN754
TN754B
TN2181
TN2224B/
CP
8
8
16
24
4-wire
DCP
4-wire
DCP
2-wire
IDCP
2-wire
IDCP
mu-law
A-law/
mu-law
A-law/
mu-law
A-law/
mu-law
7400 series digital voice
terminals, attendant consoles,
510D personal terminals,
MT515 BCTs, DCP data
modules
TN2136
TN2181
TN2224B/
CP
8
16
24
2-Wire
IDCP
2-wire
IDCP
2-wire
IDCP
A-law/
mu-law
A-law/
mu-law
A-law/
mu-law
Data Adaptors (DA), Italtel
Digital Telephone Models 1 and
2 (IDT1/2).