Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
MMI-PT
Issue 1 June 2005 1671
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description and follow its procedures.
b. Error Type 1: the customer endpoint connected on a conference sent too many messages
to the VSP-MCU in a specified amount of time. Check status conference to correlate
which customer had the problem. This is a customer endpoint problem, not a VSP-MCU
problem.
c. Error Type 18: this port was busied out by busyout port location.
d. Error Type 130: the circuit pack was removed or has been insane for more than 11 minutes.
To clear the error, replace or reseat the circuit pack.
e. Error Type 257: the MMI circuit pack detects a DSP Error. Maintenance software resets the
DSP when this error is received. This error is logged for all 8 resources connected to this
particular DSP. If this DSP continues to fail sanity, a Minor alarm is raised. Replace the
circuit pack.
f. Error Type 513: the Resource Loop-around test (#1111) fails. Run the long test sequence,
and note the results of Test #1111.
g. Error Type 1025: either the MMI or Voice Conditioner (VC) circuit packs reports a loss of
framing on the service channel between these two circuit packs. When a customer endpoint
establishes a call to the VSP-MCU, a channel is established between the MMI resource and
the VC port. If this channel is detected to go down by either circuit pack, an uplink message
is sent. This error is then forwarded to maintenance for both circuit packs. Run the long test
sequence for this MMI resource, and if any of the tests fail, follow the repair procedures for
that test. If every test passes, the cause of the problem might be with the VC pack. See the
VC-DSPPT
on page 2513 repair procedures.
513 (f) Any Resource
Loop-Back test
(#1111)
MIN ON test port location sh r 3
1025 (g
) Any Uplink error from
pack
3841 to
3844 (h
)
Any Uplink error from
pack
Table 618: MMI-PT Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2