Communication Manager Maintenance-Object Repair Procedures
1660 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
System Technician-Demanded Tests:
Descriptions and Error Code
Investigate tests in the order presented when inspecting errors in the system. By clearing Error
Codes associated with the first test, you may also clear errors generated from other tests in the
sequence.
TSI Crosstalk Test (#6)
This test is nondestructive.
The Time Slot Interchanger (TSI) chip controls connectivity to the TDM bus. The TSI Cross Talk
test verifies that this TSI talks on the selected TDM bus time slot and never crosses over to time
slots reserved for other connections. If the TSI is not working correctly, one-way and noisy
connections may occur. If the test passes, then the TSI can communicate over the TDM bus.
This test is part of the circuit pack’s demand and scheduled long test sequence, and takes
approximately 20 to 30 seconds to complete.
Order of Investigation Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
TSI Crosstalk test (#6) X ND
TSI Loop-around test (#1108) X ND
MMI SYNC Status test (#1123) X ND
MMI SYNC Status test (#1122) X ND
Control Channel Loop-around test (#52)
2
2. Refer to the repair procedure described in XXX-BD (Common Port Circuit Pack/Media
Module) on page 2539 for a description of this test.
XX ND
SAKI Sanity test (#53)
2
XD