Communication Manager Maintenance-Object Repair Procedures
540 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
m. Error Type 1537: LAN bus time out. The circuit pack is transmitting a packet larger than
1,024 bytes. Replace the circuit pack.
n. Error Type 1538: A hyperactive ATM-EI circuit pack is generating an abnormal amount of
control messages to the processor. When this error is generated, the system automatically
resets the ATM-EI.
1. Enter reset board location for this ATM-EI circuit pack.
2. If the same error persists, replace the ATM-EI circuit pack.
23 High-level path
Remote defect
Indicator:
HP_RDI
The far end is detecting a major problem with the signal that this
board is transmitting. The transmitted payload is invalid.
1. Make sure the ATM switch port (or a MUX port, if present
between ATM switch and the ATM-EI board) is the same as the
ATM-EI circuit pack’s cable interface.
2. Run test board location. If the Test #1259 fails with Error
Code 23, connect a fiber back-to-back in a looped mode (one
strand of fiber connecting the transmit transceiver to the
receive transceiver of the board) and see if the amber LED
flash goes away.
3. If it does the problem is off-board.
4. If the amber LED continues to flash, replace the circuit pack.
24 Loss of cell
delineation
(LCD)
On board ATM framer chip is not able to frame cells based on the
cell header.
1. Reset the board (reset board location).
2. If the error persists, replace the board.
27 SIGCON_DO
WN ATM
switch high
level signal.
The board cannot communicate with the ATM switch.
1. Busyout the board (busyout board location).
2. Test the board (test board long location).
3. If Test #1260 fails, replace the board.
4. If Test #1260 passes, make sure the ATM address on both the
S8700 Multi-Connect and the ATM switch sides are the same
for this board.
5. If the address is the same, change the port on the ATM switch
side. This could require administration on the ATM switch.
6. If the error is resolved, the problem is on the ATM switch port.
Duplicated PNC? Then:
Yes service to the PN is disrupted
No the system switches to the standby PNC
Table 172: Error type 1281 Aux Data and repair procedures (continued)
Aux
Data
Alarm
Description
Repair procedure
3 of 3